Menu
Cart Cart

Simple Guide to Common Bolt Strength Grades

Metric Bolt Strength Testing

Selecting the Correct Bolt

Selecting a bolt is not simply a matter of choosing the strongest available option. The fastener must suit the connection design, applied loads, joint geometry, installation method, operating temperature, corrosion exposure and governing specification.

What metric property classes mean

Metric carbon-steel and alloy-steel bolts, screws and studs are commonly identified by property classes such as 4.6, 8.8, 10.9 and 12.9. The designation indicates nominal tensile strength and the relationship between yield or proof strength and tensile strength.

For a property class x.y:

  • The first number multiplied by 100 gives the nominal tensile strength in MPa.
  • The second number divided by 10 gives the nominal ratio between yield strength and tensile strength.
  • Multiplying both numbers together and then by 10 gives the nominal yield-strength value.

Example: property class 8.8 indicates a nominal tensile strength of 800 MPa and a nominal yield strength of 640 MPa. These calculations explain the designation, but the specified minimum properties must be confirmed from the applicable standard because requirements can vary with fastener size and product conditions.

Property class 4.6

Class 4.6 fasteners have a minimum tensile strength of 400 MPa and a minimum yield strength of 240 MPa. They are generally carbon-steel fasteners without quench-and-temper heat treatment. They can be suitable for lightly loaded, general-purpose connections where high preload or high tensile capacity is not required. Suitability must still be checked against the actual loading and project specification.

Typical applications may include:

  • Light mechanical assemblies
  • Equipment covers and enclosures
  • Furniture and storage systems
  • Light brackets, gates and fencing components

Property class 8.8

Class 8.8 is widely used in engineering, machinery and construction. Up to M16, the minimum tensile strength is 800 MPa and minimum yield strength is 640 MPa. Above M16, the specified minimum values increase to 830 MPa and 660 MPa respectively. These fasteners are normally manufactured from suitable carbon, boron or alloy steel and quenched and tempered.

Typical applications may include:

  • Machinery and equipment assembly
  • Pumps, conveyors and compressors
  • Automotive and transport equipment
  • Steelwork connections where the complete bolting assembly complies with the governing requirements

Property class 10.9

Class 10.9 fasteners have a minimum tensile strength of 1,040 MPa and minimum 0.2% proof strength of 940 MPa. They are commonly produced from alloy or boron steel and quenched and tempered. A change from class 8.8 to 10.9 is not automatically a like-for-like substitution and should be accepted by the connection designer.

Typical applications may include:

  • Highly loaded machinery
  • Earthmoving and material-handling equipment
  • Axle and suspension assemblies
  • Mining and processing equipment

Property class 12.9

Class 12.9 fasteners have a minimum tensile strength of 1,220 MPa and minimum 0.2% proof strength of 1,100 MPa. They are used in selected highly loaded and specialised mechanical applications. Higher strength does not automatically make class 12.9 the safest choice. The complete joint, installation method, coating and service environment must be assessed.

Typical applications may include:

·         Highly loaded machine assemblies

·         Tooling, dies and production equipment

·         Precision machinery

·         Selected hydraulic and mechanical equipment

Property Class Is Only Part of Bolt Selection

Bolt strength at a glance

The table below provides a quick comparison of common metric bolt property classes and their minimum strength requirements.

Property class

Minimum tensile strength

Minimum yield or proof strength

General description

4.6

400 MPa

240 MPa

Lower-strength general-purpose fastening

4.8

420 MPa

340 MPa

General fastening and light mechanical applications

5.8

520 MPa

420 MPa

General mechanical fastening

8.8, up to M16

800 MPa

640 MPa

High-strength engineering and construction applications

8.8, above M16

830 MPa

660 MPa

Size-dependent class 8.8 minimum properties

10.9

1,040 MPa

940 MPa

Highly loaded machinery and engineered connections

12.9

1,220 MPa

1,100 MPa

Very highly loaded and specialised assemblies

 Note: These are reference minimum values. Confirm the applicable product size, configuration and current controlling standard before design, specification or procurement.

Understanding Tensile Strength, Yield Strength and Proof Load

Tensile strength is the maximum tensile stress reached during a tensile test. Yield strength identifies the stress at which permanent deformation begins. Proof stress is a specified stress used to verify that a fastener can sustain an established loading level without unacceptable permanent deformation. Proof load is a force for a specific fastener size, not a material stress. It depends on the specified proof stress and the thread tensile stress area.

Property Class Is Only Part of Bolt Selection

Stainless-steel Fasteners use a Different System

Designations such as A2-70 and A4-80 belong to a different classification system from carbon-steel and alloy-steel classes such as 8.8 and 10.9. A2 or A4 identifies the stainless-steel group, while 70 or 80 identifies the stainless fastener property class. Stainless fasteners must be assessed under the applicable stainless-steel fastener standard and should not be treated as directly equivalent to carbon-steel property classes.

Head Markings Don't Tell the Whole Story

A property-class marking provides important strength-class identification, but it does not independently verify dimensional compliance, material chemistry, heat treatment, coating suitability, batch traceability, nut and washer compatibility, or fitness for a particular structural connection.

Why Higher Strength Isn't Always Better

The correct fastener is the one that satisfies the complete connection specification. Selection should consider tension and shear actions, preload, tightening method, thread size, grip length, nut and washer compatibility, connected-material strength, fatigue, temperature, corrosion, coating, installation and traceability.

Specify the Complete Fastener

A technically complete specification may need to identify the product standard, nominal diameter, thread pitch, length, property class, nut class, washer specification, coating, corrosion protection, certification, traceability and installation requirements.

Key takeaway

Metric property classes provide essential information about fastener strength, but they are only one part of correct bolt selection. Structural, fatigue-sensitive, highly loaded or safety-critical connections should be assessed against the complete design and applicable standards. Bolt substitutions should be reviewed by the responsible engineer.